ISO 9001:2015 Certified Established 2015 • Complete Fire Solution Under One Roof
Safe Tech Fire Protection Services

Fire Protection Services & Systems

Turnkey Active & Passive Fire Engineering Conforming to IS & NBC Standards

8 Pillars of Total Protection

From first-response portable units to complex structural compartmentation and 24/7 AMC support.

IS:15683:2018 Certified

Fire Extinguishers

Complete range of portable and wheeled extinguishers engineered for high-efficiency knockdown of Classes A, B, C, D, and F fire risks.

  • Class A Rating: Proportional to multiples of 16kg wood (1A, 2A, 3A, 4A, 6A, 20A)
  • Class B Rating: Formulated for flammable liquids (21B, 34B, 55B, 89B, 144B, 233B)
IS:13039 & NBC Compliant

Fire Hydrant System

High-pressure water distribution networks, heavy-duty pumps, swiveling monitors, and hose reels engineered for industrial facilities and high-rise edifices.

  • Electrically driven main pump, Diesel engine standby pump, and automated Jockey pump
  • Industry pump sizing conforming to IS:13039: Light Hazard (1620 lpm), Ordinary Hazard (2280-4550 lpm), High Hazard (2850-6825 lpm)
NBC 2026 Part F Compliant

Automatic Sprinkler System

Automatic thermal bulb sprinkler distribution networks delivering 24/7 autonomous fire knockdown across commercial and industrial spaces.

  • Wet pipe, dry pipe, deluge, and double-interlock pre-action configurations
  • Standard response, fast response, and concealed flush ceiling sprinkler heads
Conventional, Addressable & IoT

Fire Alarm System

Early-stage detection architectures featuring optical smoke detectors, thermal sensors, manual call points, and IoT remote monitoring.

  • Conventional Fire Alarm Systems: Cost-effective zone switching technology for compact buildings
  • Addressable Fire Alarm Systems: Single-loop and multi-loop digital technology with precise device identification
Clean Agent & Inert Gas

Fire Suppression System

Waterless gaseous total flooding systems protecting mission-critical electronics, server racks, power substations, and engine enclosures.

  • Clean Agent Systems (Novec 1230 / FM200): Non-toxic, electrically non-conductive, zero ozone depletion, human safe
  • Inert Gas Systems (IG-541: 52% Nitrogen, 40% Argon, 8% CO2) for telecommunication and control rooms
IS:12458 Tested

Passive Fire Protection

Certified fire stop mortars, mineral fiber boards, and penetration seals providing 2-hour to 4-hour structural compartmentation.

  • Conforms strictly to Indian Standard IS:12458 (Fire resistance test of structures & penetrations)
  • Firex FM 71 Mortar: 75mm thickness achieves certified 2-hour fire rating (75kg / 3 bags per m²)
IS:12459 Compliant

Fire-Retardant Cable Coating

Heavy-duty ablative and intumescent coating applied over grouped electrical power cables to prevent rapid short-circuit fire propagation.

  • Applied strictly according to IS:12459 guidelines for electrical cable installations
  • Firex EC-43 coverage: 13.3 m² per 20kg bucket at 0.8mm Dry Film Thickness (DFT) (3.3 m² per 5kg bucket)
24/7 Technical Support

Service & Maintenance (AMC)

Comprehensive Annual Maintenance Contracts, statutory audits, cylinder refilling, hydrostatic testing, and mock fire drills.

  • Annual Maintenance Contracts (AMC) with scheduled quarterly, semi-annual, and annual inspections
  • Precision refilling and hydrostatic pressure testing of portable and wheeled extinguishers (IS:2190)
Specialized Engineering

Electrical Panel & Commercial Kitchen Systems

We engineer specialized systems under NBC Clause 3.4.6.3 (Fire Spot Panel Protection for server racks and motor control centers) and Clause 6 Annex G (Kitchen Hood Wet Chemical Automatic Suppression).

Compliance Highlights:

  • Direct sensor tubing suppressing electrical panel short circuits at origin
  • Stainless steel culinary hoods with automatic gas cut-off interlock
  • Zero chemical toxicity for food preparation zones and server rooms
Get a Quote

Request a Comprehensive System BOQ

Our design engineers calculate exact hydraulic requirements, mortar bags, and cable coating quantities.

Contact Engineering Team